The Testo 310 II (Part No 05633105) flue gas analyser with Printer. For reliable heating system checks
Heating fitters and technicians who perform commissioning and maintenance of hot water and residential heating systems need a reliable and stable measuring instrument with which they can easily perform their measuring tasks such as exhaust gas analyses. The new testo 310 II provides individual support for their daily measurement tasks and makes their day-to-day work easier.
Your Advantages
-
Simultaneous, individual measurement and display of all relevant measurement parameters by (O2, CO, CO2, flue gas and ambient temperature, CO environment, draught and pressure). Display configurable via the testo Smart App
-
Simultaneous, additional measurements via the testo Smart App (e.g. gas flow pressure, flow and return temperature)
-
Easy and intuitive menu guidance
-
Digital documentation, data transfer and customer data management via testo Smart App
Delivery Scope
Flue gas analyser Testo 310 II incl. rechargeable battery and calibration protocol for the measurement of O2, CO, hPa and °C, probe 180 mm with cone, silicon hose for pressure measurement, particle filters 5 off. and case
Testo 310 II, Testo 310 II flue gas analyser, Testo 310 II combustion analyser, Testo 310 II with printer, testo 310 II combustion analyser kit, combustion analyser with printer, testo 0563 3104, testo 0563 3105, residential combustion analyser, testo 310 II price, testo flue analyser, 0563 3104, 0563 3105, 310 II testo, testo 310 II analyser, testo 310 II flue gas analyser, testo 310 II combustion analyser kit with printer, testo 310 II flue gas analyser printer kit
Technical Data
Testo 310 II Technical Data
Temperature – TC Type K (NiCr-Ni)
Measuring range |
-20 to +100 °C
|
Accuracy |
±1 °C
|
Resolution |
0.1 °C
|
Reaction time |
< 50 s
|
Temperature (ambient temperature) |
Temperature – TC Type J (Fe-CuNi)
Measuring range |
0 to +400 °C
|
Accuracy |
±1 °C (0 to +100 °C)
±1.5 % of mv (> 100 °C)
|
Resolution |
0.1 °C
|
Reaction time |
< 50 s
|
Temperature (flue gas) |
Flue gas Oâ‚‚
Measuring range |
0 to 21 Vol.%
|
Accuracy |
±0.2 Vol.%
|
Resolution |
0.1 Vol.%
|
Reaction time t₉₀ |
30 s
|
|
Differential Pressure flue gas Draught – Piezoresistive
Measuring range |
-20 to +20 hPa
|
Accuracy |
±1.5 % of mv (Remaining Range)
±0.03 hPa (-3.00 to +3.00 hPa)
|
Resolution |
0.01 hPa
|
|
Flue gas degree of effectivity, Eta (calculated)
Measuring range |
0 to 120 %
|
Resolution |
0.1 %
|
|
Flue gas loss (calculated)
Measuring range |
0 to 99.9 %
|
Resolution |
0.1 %
|
|
Pressure measurement
Measuring range |
-40 to +40 hPa
|
Accuracy |
±0.5 hPa
|
Resolution |
0.1 hPa
|
|
Flue gas CO (without Hâ‚‚-compensation)
Measuring range |
0 to 4000 ppm
|
Accuracy |
±10 % of mv (2001 to 4000 ppm)
±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm)
|
Resolution |
1 ppm
|
Reaction time t₉₀ |
60 s
|
|
Ambient CO
Measuring range |
0 to 4000 ppm
|
Accuracy |
±10 % of mv (2001 to 4000 ppm)
±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm)
|
Resolution |
1 ppm
|
Reaction time |
60 s
|
|
General technical data
Weight |
Approx. 660 g
|
Dimensions |
201 x 83 x 44 mm
|
Operating temperature |
-5 to +45 °C
|
Display function |
Graphic 7-line display
|
Power supply |
Battery: 1500 mAh, mains unit 5V/1A
|
Storage temperature |
-20 to +50 °C
|